JT TRV-800D-N/TRV-1000-N/TRV-1000D-N/TRV-1200-N/TRV-1200D-N Reflow Soldering Machine
TRV Series Vacuum Assisted Reflow Oven
● Independent temperature control zone, suitable for different temperature profile;
● Solve the problem of bubble & void, <1% void area can be achieved;
● High efficient vacuum pump unit equipped for fast down time;
● 3- section conveyor : Heating zone ,vacuum unit and cooling zone , adjustable individually;
● High production throughput, cycle time 40-60sec, average;
● Equipped with high efficient flux collection system.
● High efficiency、No voids、 Low maintenance cost: Equipped with vacuum unit to solve the problem of void, bubble, etc. Voids area can reach < 1% by the vacuum pressure 10-5mbar.
● High accurate vacuum level and temperature profile: Temperature of each zone can be adjusted individually. Pressure under 10mbar still can meet TI≤90S, TP≤240°C. Infrared heating equipped in vacuum unit to meet high throughput settings.
Description
MODEL | TRV-800-N |
GENERAL | |
Outside Dimension(L*W*H) | 5520 x 1430x 1530mm |
Standard Color | Computer Grey |
Weight | Approx. 2500KG |
Number Of Heating Zones | Up 8(1IR) / Bottom 7 |
Length Of Heating Zones | 3110mm(With Vacuum Area) |
Number Of Cooling Zones | Up 3 / Bottom 3 (Cool Air Conversion) |
Exhaust Volume | 10 m³ / min x 2 (Exhausts) |
Electric Supply Required | 3 phase, 380V 50/60Hz (Optional: 3 phase, 220V 50/60Hz) |
Electric Power Required | 67KW |
Power For Warm Up | 32KW |
Power Consumption | 10KW |
Vacuum Level | 5 mbar~10 mbar |
Warming Time | About Approx. 25 minute |
Temp. Setting Range | Room Temp. — 300℃ |
Temperature Control Method | PID Close Loop Control + SSR Driving |
Temperature Control Precision | ± 1.0℃ |
Temperature Deviation on PCB | ± 1.5℃ (by JT Board Test Standard) |
Heating Element | Especial Heating elements For Long Life |
Commutated Element | Aluminium Alloy Plate |
Data Storage | Process Data and Status Storage |
Abnormal Alarm | Abnormal Temperature (Extra-high / Extra-low Temp.) |
Board Dropped Alarm | Tower Light: Yellow–Warming; Green-Normal; Red-Abnormal |
Conveyor | chain conveyor |
Rail Structure | Subsection Integrated Type |
Rang Width Of PCB | Single Lane min70mm-max430mm;Dual Lane min70mm-max250mm |
Rang Length Of PCB | min150mm-max300mm |
chiller | Standard |
Flux Collection System | Standard |
N2 Control Device | Standard |
Oxygen Analyser | Standard |
MODEL | TRV-1000-N |
GENERAL | |
Outside Dimension(L*W*H) | 6300 x 1430 x 1530mm |
Standard Color | Computer Grey |
Weight | Approx.2800KG |
Number Of Heating Zones | Up 10(1IR) / Bottom9 |
Length Of Heating Zones | 3890mm(With Vacuum Area) |
Number Of Cooling Zones | Up 3 / Bottom 3 (Cool Air Conversion) |
Exhaust Volume | 10 m³ / min x 2 (Exhausts) |
Electric Supply Required | 3 phase, 380V 50/60Hz (Optional: 3 phase, 220V 50/60Hz) |
Electric Power Required | 83KW |
Power For Warm Up | 38KW |
Power Consumption | 11KW |
Vacuum Level | 5 mbar~10 mbar |
Warming Time | About Approx. 25 minute |
Temp. Setting Range | Room Temp. — 300℃ |
Temperature Control Method | PID Close Loop Control + SSR Driving |
Temperature Control Precision | ± 1.0℃ |
Temperature Deviation on PCB | ± 1.5℃ (by JT Board Test Standard) |
Heating Element | Especial Heating elements For Long Life |
Commutated Element | Aluminium Alloy Plate |
Data Storage | Process Data and Status Storage |
Abnormal Alarm | Abnormal Temperature (Extra-high / Extra-low Temp.) |
Board Dropped Alarm | Tower Light: Yellow–Warming; Green-Normal; Red-Abnormal |
Conveyor | chain conveyor |
Rail Structure | Subsection Integrated Type |
Rang Width Of PCB | Single Lane min70mm-max430mm;Dual Lane min70mm-max250mm |
Rang Length Of PCB | min150mm-max300mm |
chiller | Standard |
Flux Collection System | Standard |
N2 Control Device | Standard |
Oxygen Analyser | Standard |
MODEL | TRV-1000D-N |
GENERAL | |
Outside Dimension(L*W*H) | 6300 x 1660 x 1530mm |
Standard Color | Computer Grey |
Weight | Approx.3200KG |
Number Of Heating Zones | Up 10(1IR) / Bottom9 |
Length Of Heating Zones | 3890mm(With Vacuum Area) |
Number Of Cooling Zones | Up 3 / Bottom 3 (Cool Air Conversion) |
Exhaust Volume | 10 m³ / min x 2 (Exhausts) |
Electric Supply Required | 3 phase, 380V 50/60Hz (Optional: 3 phase, 220V 50/60Hz) |
Electric Power Required | 83KW |
Power For Warm Up | 40KW |
Power Consumption | 12KW |
Vacuum Level | 5 mbar~10 mbar |
Warming Time | About Approx. 25 minute |
Temp. Setting Range | Room Temp. — 300℃ |
Temperature Control Method | PID Close Loop Control + SSR Driving |
Temperature Control Precision | ± 1.0℃ |
Temperature Deviation on PCB | ± 1.5℃ (by JT Board Test Standard) |
Heating Element | Especial Heating elements For Long Life |
Commutated Element | Aluminium Alloy Plate |
Data Storage | Process Data and Status Storage |
Abnormal Alarm | Abnormal Temperature (Extra-high / Extra-low Temp.) |
Board Dropped Alarm | Tower Light: Yellow–Warming; Green-Normal; Red-Abnormal |
Conveyor | chain conveyor |
Rail Structure | Subsection Integrated Type |
Rang Width Of PCB | Single Lane min70mm-max430mm;Dual Lane min70mm-max250mm |
Rang Length Of PCB | min150mm-max300mm |
chiller | Standard |
Flux Collection System | Standard |
N2 Control Device | Standard |
Oxygen Analyser | Standard |
MODEL | TRV-1200-N |
GENERAL | |
Outside Dimension(L*W*H) | 7050 x 1430 x 1530mm |
Standard Color | Computer Grey |
Weight | Approx. 3100KG |
Number Of Heating Zones | Up 12(1IR) / Bottom 11 |
Length Of Heating Zones | 4640mm(With Vacuum Area) |
Number Of Cooling Zones | Up 3 / Bottom 3 (Cool Air Conversion) |
Exhaust Volume | 10 m³ / min x 2 (Exhausts) |
Electric Supply Required | 3 phase, 380V 50/60Hz (Optional: 3 phase, 220V 50/60Hz) |
Electric Power Required | 105KW |
Power For Warm Up | 42KW |
Power Consumption | 12KW |
Vacuum Level | 5 mbar~10 mbar |
Warming Time | About Approx. 25 minute |
Temp. Setting Range | Room Temp. — 300℃ |
Temperature Control Method | PID Close Loop Control + SSR Driving |
Temperature Control Precision | ± 1.0℃ |
Temperature Deviation on PCB | ± 1.5℃ (by JT Board Test Standard) |
Heating Element | Especial Heating elements For Long Life |
Commutated Element | Aluminium Alloy Plate |
Data Storage | Process Data and Status Storage |
Abnormal Alarm | Abnormal Temperature (Extra-high / Extra-low Temp.) |
Board Dropped Alarm | Tower Light: Yellow–Warming; Green-Normal; Red-Abnormal |
Conveyor | chain conveyor |
Rail Structure | Subsection Integrated Type |
Rang Width Of PCB | Single Lane min70mm-max430mm;Dual Lane min70mm-max250mm |
Rang Length Of PCB | min150mm-max300mm |
chiller | Standard |
Flux Collection System | Standard |
N2 Control Device | Standard |
Oxygen Analyser | Standard |
TRV Series | |
MODEL | TRV-1200D-N |
GENERAL | |
Outside Dimension(L*W*H) | 7050 x 1660 x 1530mm |
Standard Color | Computer Grey |
Weight | Approx. 3500KG |
Number Of Heating Zones | Up 12(1IR) / Bottom 11 |
Length Of Heating Zones | 4640mm(With Vacuum Area) |
Number Of Cooling Zones | Up 3 / Bottom 3 (Cool Air Conversion) |
Exhaust Volume | 10 m³ / min x 2 (Exhausts) |
Electric Supply Required | 3 phase, 380V 50/60Hz (Optional: 3 phase, 220V 50/60Hz) |
Electric Power Required | 105KW |
Power For Warm Up | 44KW |
Power Consumption | 13KW |
Vacuum Level | 5 mbar~10 mbar |
Warming Time | About Approx. 25 minute |
Temp. Setting Range | Room Temp. — 300℃ |
Temperature Control Method | PID Close Loop Control + SSR Driving |
Temperature Control Precision | ± 1.0℃ |
Temperature Deviation on PCB | ± 1.5℃ (by JT Board Test Standard) |
Heating Element | Especial Heating elements For Long Life |
Commutated Element | Aluminium Alloy Plate |
Data Storage | Process Data and Status Storage |
Abnormal Alarm | Abnormal Temperature (Extra-high / Extra-low Temp.) |
PREVIOUS:JT TFO1000/TFO800/TFO800D/TFO1000D/Reflow Soldering Machine NEXT:JT MFO-800/MFO-800-N/MFO-1000/MFO-1000-N/MFO-1200/MFO-1200-N Reflow Soldering Machine
|